1.1.3 Category III – Educational and Industrial – This shall comprise partly Group C, D, E, and H Buildings 1.1.4 Category IV â€�� Agriculture – This shall comprise partly Group J Buildings. 1.1.5 Category V – Ancillary – This shall comprise partly Group J Buildings. 2. ARCHITECTURAL FEATURES AND FACILITIES: Where the following features and facilities are: architectural design requirements in accordance with generally accepted architectural practice, the same include the corresponding graphic signs. 2.1 Architectural facilities and features: 2.1.1 A – Stairs 2.1.2 B – Walkways 2.1.3 C – Corridors 2.1.4 D – Doors and Entrance 2.1.5 E – Washrooms and Toilets 2.1.6 F – Lifts/Elevator 2.1.7 G – Ramps 2.1.8 H – Parking Areas 2.1.9 I – Switches, Controls, Buzzers 2.1.10 J – Handrails 2.1.11 K – Thresholds 2.1.12 L – Floor Finishes 2.1.13 M – Drinking Fountains 2.1.14 N – Public Telephones 2.1.15 O – Seating Accommodations 3. CATEGORY I The following requirements shall only apply to government-owned building: 3.1 Group A 3.1.1 Single detached. Ten percent (10%) of the total units to be constructed. Barrierfree facilities and features required in: A, B, C, D, E, G, H, I, J, K, and L. 3.1.2 Duplexes: Ten percent (10%) of the total units to be constructed. Barrier-free facilities and features required in: A, B, C, D, E, G, H, I, J, K, and L. 3.1.3 School or company staff housing units: One (1) unit for 26 to 50 units to be constructed and 1 additional unit for every 100 units thereafter. Barrier-free facilities and features required in: A, B, C, D, E, G, H, I, J, K, and M. 4. Category II The following requirement shall apply to both government and privately owned buildings. 4.1 Group B 4.1.1 Accessories, tenement houses and/or row houses, apartment houses and/or town houses. One (1) unit for every 50 units up to 150 units and an additional unit for every 100 units thereafter. Barrier-free facilities and features required in: A, B, C, D, E, G, H, I, J, K, and L. 4.1.2 Hotels, motels, inns, pension houses and/or apartels. One (1) unit per every 50 units up to 150 units and additional unit for every 100 units at ingress level. In case there is no barrier-free elevators: at least one (1) unit shall be provided at ingress level. Barrier-free facilities and features required in: A, B, C, D, E, F, G, H, I, J, K, L, M, and N. 4.1.3 Private or off campus Dormitories: One (1) unit per every 50 unit up to150 units and additional dwelling unit for every 100 units thereafter at ingress level. Barrier-free facilities and features required in: A, B, C, D, E, G, H, I, J, K, L, M, and N. 4.2 Group C 4.2.1 Amusement Halls and Parlor Barrier-free facilities and features required in A, B, C, D, E, F, G, H, I, J, K, L, M, N, and O. 4.2.2 Massage and Sauna Parlors Barrier-free facilities and features required in A, B, C, D, E, F, G, H, I, J, K, L, and M. 4.3 Group E-1 4.3.1 Train Stations and Terminals Barrier-free facilities and features required in A, B, C, D, E, F, G, H, I, J, K, L, M, N, and O. 4.3.2 Bus depots and Terminals Barrier-free facilities required in A, B, C, D, E, F, G, H, I, J, K, L, M, N, and O. 4.3.3 Transportation Office Barrier-free facilities required in A, B, C, D, E, F, G, H, I, J, K, L, M, N, and O. 4.3.4 Airport terminal buildings, heliports Barrier-free facilities required in A, B, C, D, E, F, G, H, I, J, K, L, M, N, and O.

Select target paragraph3